SM enomodni G652D GYTA 24fibers direktno zakopan zunanji optični kabel
Tehnični podatki kabla GYTA
| Vrsta kabla | Število vlaken | Cevi | Polnila | Premer kabla mm | Teža kabla kg/km | Natezna trdnost Dolgoročno/kratkoročno N | Odpornost na drobljenje Dolgoročno/kratkoročno N/100 mm | Polmer upogibanja Statično mm |
| GYTA-2~12 | 8~12 | 1 | 4 | 9,0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-14~18 | 14~18 | 3 | 2 | 9,0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-20~24 | 20~24 | 4 | 1 | 9,5 | 110 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-26~36 | 26~36 | 4 | 1 | 9,5 | 120 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-38~48 | 38~48 | 4 | 1 | 10,0 | 140 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-50~60 | 50~60 | 5 | 0 | 10,8 | 150 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-62~72 | 62~72 | 6 | 0 | 11,9 | 170 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-74~84 | 74~84 | 7 | 1 | 12,5 | 180 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-86~96 | 86~96 | 8 | 0 | 13,6 | 210 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-98~108 | 98~108 | 9 | 1 | 14,5 | 230 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-110~120 | 110~120 | 10 | 0 | 14,8 | 240 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTS-122~144 | 122~132 | 11 | 1 | 15,4 | 260 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-146~216 | 146~216 | 12 | 0 | 19,8 | 395 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-218~288 | 218~288 | 12 | 0 | 20,8 | 470 | 1000/3000 | 1000/3000 | 10D/20D |
Značilnost vlaken:
| Slog vlaken | Enota | SM G652D | SM G657A | MM 50/125 | MM 62,5/125 | MM OM3-300 | MM OM4-550 | |
| Stanje | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Slabljenje | dB/km | ≤0,34/0,22 | ≤ 0,035/0,21 | ≤3,0/1,0 | ≤3,0/1,0 | ≤3,0/1,0 | ≤3,5/2,2 | |
| Disperzija | 1550 nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625 nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Pasovna širina | 850 nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300 nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Valovna dolžina ničelne disperzije | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Naklon ničelne disperzije | nm | ≤0,091 | ≤0,090 | ---- | ---- | ---- | ---- | |
| PMD Največja posamezna vlakna | ≤0,2 | ≤0,2 | ---- | ---- | ≤0,11 | |||
| Vrednost povezave zasnove PMD | Ps(nm2*km) | ≤0,08 | ≤0,1 | ---- | ---- | ---- | ---- | |
| Mejna valovna dolžina vlakna λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Prekinitev kabla valovna dolžina λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| Večfunkcijska naprava | 1310 nm | um | 9,2±0,4 | 9,0±0,4 | ---- | ---- | ---- | ---- |
| 1550 nm | um | 10,4±0,8 | 10,1±0,5 | ---- | ---- | ---- | ---- | |
| Numerično Zaslonka (NA) | ---- | ---- | 0,200± 0,015 | 0,275± 0,015 | 0,200± 0,015 | 0,200± 0,015 | ||
| Korak (povprečje dvosmernega meritev) | dB | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ≤0,10 | |
| Nepravilnosti glede dolžine in konice vlaken | dB | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ≤0,10 | |
| Razlika povratnega sipanja koeficient | dB/km | ≤0,03 | ≤0,03 | ≤0,08 | ≤0,10 | ≤0,08 | ≤0,08 | |
| Enakomernost slabljenja | dB/km | ≤0,01 | ≤0,01 | |||||
| Premer jedra | um | 9 | 9 | 50±1,0 | 62,5±2,5 | 50±1,0 | 50±1,0 | |
| Premer obloge | um | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | |
| Nekrožnost obloge | % | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | |
| Premer prevleke | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Premaz/cigana koncentrična napaka | um | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | |
| Nekrožnost premaza | % | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | |
| Napaka koncentričnosti jedra/ovojnice | um | ≤0,6 | ≤0,6 | ≤1,5 | ≤1,5 | ≤1,5 | ≤1,5 | |
| Zavoj (polmer) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Barva vlaken:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Modra | Oranžna | Zelena | Rjava | Siva | Bela |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Rdeča | Črna | Rumena | Vijolična | Roza | Vodna |
Opis kabla GYTA
+ Vlakna, velikosti 250 μm, so nameščena v ohlapni cevi iz visokomodularne plastike.
+ Cevi so napolnjene z vodoodporno polnilno maso.
+ Jeklena žica, včasih oplaščena s polietilenom (PE) za kable z visokim številom vlaken, se nahaja v središču jedra kot kovinski trdnostni element.
+ Cevi (in polnila) so navite okoli nosilnega elementa v kompaktno in krožno kabelsko jedro.
+ EnAluminijasto-polietilenski laminat (APL)se nanese okoli kabelskega jedra, ki je napolnjeno s polnilno maso, da ga zaščiti pred vdorom vode.
+ Kabel je opremljen s PE plaščem.
Gradnja:
Značilnosti kabla GYTA:
+ Dobre mehanske in temperaturne lastnosti
+ Visoko trdna ohlapna cev, odporna na hidrolizo
+ Posebna polnilna masa za cevi zagotavlja kritično zaščito vlaken
+ Posebej zasnovana kompaktna struktura preprečuje krčenje ohlapnih cevi
+ PE plašč ščiti kabel pred ultravijoličnim sevanjem
+ Za zagotovitev vodotesnosti kabla so sprejeti naslednji ukrepi:
+ Jeklena žica kot osrednji nosilni element
+ Polnilna masa za cevke
+ 100 % zapolnitev kabelskega jedra
+ 100% preizkušeno pred odpremo.
+ Dolžina kabelskega koluta: 1 km, 2 km, 3 km, 5 km
Uporaba kabla GYTA:
+ Prilagojeno za zunanjo distribucijo.
+ Primerno za polaganje cevovodov, neposredno zakopavanje, podzemno metodo.
+ Komunikacija na dolge razdalje in v lokalnem omrežju.
Pakiranje: